Online UPS 3 Phase & Single Phase O/P-PS 31 Series

BP 650
Key Features & Application

 

    • High frequency and double conversion on-line technology
    • Advanced PFC technology, >0.99
    • 3U frame, rack-mounted and tower convertible
    • EPO function
    • Wide input voltage range
    • Fully digitized DSP control
    • lnbullt Parallel redundancy
    • Advanced battery management
    • Lightning and surge protection, short circuit and
      overload poteclion
    • Multilingual LCD and LED display
    • EMIIRFI noise filter
    • Smart RS232 communication with monitoring software
    • Optional SNMP card slot
    • Paralleling of rack upto 4
    • lnbuilt granular power Paralleling
    • Being output power factor is 1all KVA module are KW rated.
Model PS 31 Series
Three Phase input & Single phase Output
INPUT                                                                           380/400/415Vac, (3Ph+N+PE)
Nominal Voltage 208~478 Vac
Operating Voltage range 40Hz – 70Hz
Operating frequency range >-0.99
Power factor                                                                5%(100% nonlinear load)
Harmonic distortion (THDi)
Bypass voltage range  Max. voltage: 220V:+25%(optional + 10%,+15%+20%); 230V: +20%(optional+10%, 15%); 240V: +15%(optional+10%)Min . voltage: -45% (optional-20%, -30%)
Bypass frequency range Frequency protection range:+-10%
Generator input Support
Overload 125% : 1min, 150%: 200ms
Output
Rated Voltage 220/230 Vac
Power factor  1.0(6KVA=6KW, 10KVA=10KW,20KAV=20KW,30KVA=30KW,40KVA=40KW
Voltage regulation  +-1%
Output frequency   +1%/+2%/+4%/+5%/+10% of the rated frequency (Selectable) Mains Mode(50/60+-0.1%) Hz Free Running
Isolation transformer Available
Creat factor 3:1
Harmonic distortion (THDi)  <-2% with linear load,<-5% with non linear load
Effciency 94.0%
BATTERY
Battery voltage  +-96V/+-108V/+-120Vdc
Charge Current (A)  6A (Max) per module , (charge current can be set according to batery capacity insatted)
SYSTEM FEATURES
Transfer time Utility to Battery : 0ms; last 10min,<-150%:last 1min
Overload  Load <110%:last 60min, <125% :last 10min, <150%:last 1min
Short Circuit Hold Whole System
OverheatNoise suppression

Audible & visual alarms

Status LED & LCD display

Reading on the LCD display

Communication interface

ENVIRONMENTTAL

Operating temperature

Storage temperature

Humidity range

Altitude

Noise level (from 1M distance)

STANDARDS

Safety

EMC

Line  Mode : Switch to Bypass; Backup Mode : Sut down UPS Immediately

Complies with EN62040-2

Line Failure, Battery Low ,Overload,System Fault

Line Mode , Bypass Mode, Battery Low, Battery Bad,overload & UPS fault

Input,Output,Battery,command,setting,maintenance

RS232,RS485,Parallel,Intelligent slot,Relay card (optional),Battery temperature sentor (optional)

0℃ ~40℃

-25℃~55℃

0~95%(non condensing)

<1500m

<55dB

IEC/EN62040-1; IEC/EN60950-1

IEC/EN62040-2; IEC61000-4-2; IEC61000-4-3; IEC61000-4-4;

IEC61000-4-5; IEC61000-4-6; IEC61000-4-8